Hopkinsons®
Full Bore & Venturi Parallel Slide Gate
The outstanding feature of the parallel slide design is that of maintaining fluid-tightness without the aid of wedging action. No mechanical stress is exerted between the discs, and there are no problems associated with cool-down of the fluid.
VENTURI DESIGN
-
The Venturi design is used when a slightly higher pressure drop is acceptable. The well established principle of fluid flow through a Venturi is used in order to minimise pressure drop. Venturi valves incorporate the design feature of an eye follower.
-
In the fully open position, the eye follower bridges the gap between the seats thus giving a smooth flow path and completing the Venturi profile.
KEY FEATURES & BENEFITS
-
Fluid tightness achieved by fluid pressure, not from mechanical wedging action thus eliminating thermal binding
-
Complete flow isolation in either direction
-
Minimum pressure drop
-
Freedom from leakage independent of temperature or pressure changes
-
Self-aligning fully supported discs
-
Inherent self-cleaning action
-
In-line maintenance
-
Valves can be offered to incorporate features such as quick closure, live loaded gland, double stuffing box with lantern ring and bleed-off point, back seat, seal welded body & cover joint
APPLICATIONS
-
General purpose stop valve
-
Main steam and feedwater isolation
-
Boiler circulating pump isolation
-
The basic design is also incorporated in valves for other duties such as: Feedwater heater protection; Feed pump leak-off; Nuclear Applications (ASME Section III, Class 1, 2 & 3) (Described in other publications available on request); Regulating duty with V-ported seat
DESIGN STANDARDS
-
ASME B16.34.
-
Alternatively, valves can be supplied to other national standards.
-
ASME section IIIRCC-M
DESIGN RATINGS
-
ASME Class 150 to 4500
SIZE RANGE & DIMENSIONS
-
15 – 1200 mm (0.5 – 48 inches)
TEMPERATURE RANGE
-
29°C – 620°C (-20°F – 1150°F)
MATERIALS
-
Carbon Steel
-
Alloy Steel
-
Stainless Steel
-
Bronze